Saturday, September 3, 2016

Moisture Intrusion: We Inspect For That

Moisture intrusion can be the cause of building defects, as well as health ailments for the building's occupants. Inspectors should have at least a basic understanding of how moisture may enter a building, and where problem areas commonly occur.

Some common moisture-related problems include:
  • structural wood decay; 
  • high indoor humidity and resulting condensation;
  • expansive soil, which may crack the foundation through changes in volume, or softened soil, which may lose its ability to support an overlying structure;
  • undermined foundations;
  • metal corrosion;
  • ice dams; and
  • mold growth.  Mold can only grow in the presence of high levels of moisture. People who suffer from the following conditions can be seriously (even fatally) harmed if exposed to elevated levels of airborne mold spores:
    • asthma;
    • allergies;
    • lung disease; and/or
    • compromised immune systems.
Note:  People who do not suffer from these ailments may still be harmed by elevated levels of airborne mold spores.
How does moisture get into the house?
Moisture or water vapor moves into a house in the following ways:
  • air infiltration. Air movement accounts for more than 98% of all water vapor movement in building cavities. Air naturally moves from high-pressure areas to lower ones by the easiest path possible, such as a hole or crack in the building envelope. Moisture transfer by air currents is very fast (in the range of several hundred cubic feet of air per minute). Replacement air will infiltrate through the building envelope unless unintended air paths are carefully and permanently sealed;
  • by diffusion through building material. Most building materials slow moisture diffusion, to a large degree, although they never stop it completely;
  • leaks from roof;
  • plumbing leaks; 
  • flooding, which can be caused by seepage from runoff or rising groundwater; it may be seasonal or catastrophic; and
  • human activities, including bathing, cooking, dishwashing and washing clothes. Indoor plants, too, may be a significant source of high levels of humidity.
Climate Zones
In the northern U.S., moisture vapor problems are driven primarily by high indoor relative humidity levels, combined with low outdoor temperatures during the winter. In the southern U.S. (especially the southeast), the problem is largely driven by high outdoor humidity and low indoor temperatures during summer months. Mixed climates are exposed to both conditions and can experience both types of problems. Humid climates, in general, will be more of a problem than dry climates. Wind-driven rain is the main cause of leaks through the building envelope.
Inspectors can check for moisture intrusion in the following areas:
Roofs
A roof leak may lead to the growth of visible mold colonies in the attic that can grow unnoticed. Roof penetrations increase the likelihood of water leaks due to failed gaskets, sealants and flashing. The number of roof penetrations may be reduced by a variety of technologies and strategies, including: 
  • consolidation of vent stacks below the roof;
  • exhaust fan caps routed through walls instead of the roof;
  • high-efficiency combustion appliances, which can be sidewall-vented;
  • electrically powered HVAC equipment and hot water heaters that do not require flue; and
  • adequate flashing. Oftentimes, inspectors discover missing, incorrectly installed or corroded flashing pipes.
Plumbing
  • Distribution pipes and plumbing fixtures can be the source of large amounts of moisture intrusion. If the wall is moist and/or discolored, then moisture damage is already in progress. Most plumbing is hidden in the walls, so serious problems can begin unnoticed.
  • One of the most important means of moisture management in the bathroom is the exhaust fan. A non-functioning exhaust fan overloads the bathroom with damp air. If the exhaust fan doesn’t turn on automatically when the bathroom is in use, consider recommending switching the wiring or switch. The lack of an exhaust fan should be called out in the inspection report. The fan should vent into the exterior, not into the attic.
  • The bathroom sink, in particular, is a common source of moisture intrusion and damage. Although overflow drains can prevent the spillage of water onto the floor, they can become corroded and allow water to enter the cabinet.  
  • Use a moisture meter to check for elevated moisture levels in the sub-floor around the toilet and tub.
  • Bathroom windows need to perform properly in a wide range of humidity and temperature conditions. Check to see if there are any obvious breaks in the weatherstripping and seals. Are there are stains or flaking on the painted surfaces?
  • Check showers and bathtubs. Is the caulking is cracked, stiff or loose in spots? Are there cracked tiles or missing grout that may channel water to vulnerable areas? If some water remains in the bathtub after draining, it may be a warning sign of possible structural weakening and settlement in the floor beneath the tub.
Utility Room
  • The water heater tank should be clean and rust-free.
  • The area around the water softener tank should be clean and dry.
  • Check that all through-the-wall penetrations for fuel lines, ducts, and electrical systems of heating system are well-sealed. All ducts should be clean and dust-free. Inspect the air supply registers in the house for dust accumulation.   
  • Filters, supply lines, exterior wall penetrations, vents, ductwork and drainage of the cooling system must all be in good working order to avoid moisture problems.  
Attic
  • Look for stains or discolorations at all roof penetrations. Chimneys, plumbing vents and skylight wells are common places where moisture may pass through the roof. Any such locations must be inspected for wetness, a musty smell and/or visible signs of mold.
  • Are there areas of the insulation that appear unusually thin?
  • Rust or corrosion around recessed lights are signs of a potential electrical hazard.
Foundations

Model building codes typically require damp-proofing of foundation walls. The damp-proofing shall be applied from the top of the footing to the finished grade. Parging of foundation walls should be damp-proofed in one of the following ways:
  • bituminous coating;
  • 3 pounds per square yard of acrylic modified cement;
  • 1/8-inch coat of surface-bonding cement; or
  • any material permitted for water-proofing.

In summary, moisture can enter a building in a number of different ways. High levels of moisture can cause building defects and health ailments. 

To schedule your home inspection including a detailed check for moisture intrusion, visit www.vhillc.com

by Nick Gromicko and Kenton Shepard

 https://www.nachi.org/moisture-intrusion.htm

Saturday, January 31, 2015

What were they thinking?

As promised, a summary of the interesting things I found on yesterday's home inspections.  These were two nice looking homes that had some serious issues.  Enjoy!

As Paul Harvey would have said, here is the rest of the story on the teaser video I posted yesterday.  When my client and I were in the crawlspace, I bumped into a support pillar, and it moved, a lot!  There were several pillars installed with dry-stacked cinder blocks (no mortar at all).  They were all loose, and no longer providing support to the beams supporting the floor joists.  They may have provided support when they were installed, but without the necessary footers, they had settled and were no longer supporting the beams.


The three columns in this picture were all loose, and yes, that first one really was leaning as much as it appears.  The beam above it was quite loose and could be moved by hand.


While in the crawlspace, we noticed a lot of water on the underside of the vapor barrier.



Unfortunately, the vapor barrier was only partially installed, which was probably the cause of the increased moisture in the crawlspace materials.


This is the reading from the moisture meter in the above picture.  As you can see, it's wet!  This can not only lead to mold, but also rot and wood destroying insect infestation.



Which might have been the cause of the mold-like substance we found growing on the joists and subfloor.


Or maybe the moisture was coming from the sewage leaking from the drain lines.



Either way, it was causing a lot of corrosion to the electrical system components.


This is what happens when your toilet is loose and the wax ring doesn't seal anymore.


The attic wasn't immune to moisture problems either.  Where do your bathroom exhaust fans terminate.  The correct answer should be outside.  The black stuff on the underside of the roof sheathing wasn't paint...


And the electrical issues continued in the attic too!


Those were all just from the morning inspection.  Now on to the afternoon inspection.

The electrical in this attic was just as good as the first house.  


The yellow and orange wires were connected to a plug and then ran across the attic to a bedroom closet ceiling light.


These wires almost made it to the junction box, I guess the electrician didn't have his wire stretcher with him.


There are a couple issues in this picture.  First, the duct work is the supply side, and is not insulated.  This can be a huge energy loss and they should have used insulated duct work.  The other issue, is a bit more serious.  The metal tab on the rafter is where a truss member used to be.  I guess the HVAC duct was more important than the roof support.


Of course when you look at how they installed the HVAC itself, you get the idea that maybe this wasn't a professional job.  The outside AC compressor was from 2001, and I would guess the inside unit was the same.  I can only guess, because that vertical truss member was obscuring the data plate.  It was also preventing the access cover from being removed, so I'd pretty much guarantee the inside of the unit has never been checked or cleaned.  


This is the view of the fireplace flue looking from the attic above the 2nd floor all the way to the fireplace on the first floor.  In the unfortunate event of a fire, it would be able to quickly spread from the first floor to the attic.  This is one of the primary reasons we stopped using balloon construction in houses.


These are the drain lines for what I suspect is an unpermitted half bath. Drain lines are not supposed to be this steep, unless they are more than 45 degrees down angle.  Steep slopes (more than 1/2":12" up to 45 degree supposedly lead to clogs as the water leads the solids behind.  


This was a floor joist in the new addition (done with a permit) but the code inspector missed this one.  For some reason plumbers forget to reinforce the joists the hack away when they need to run their plumbing in the same place.



That's all for now folks.  Stay safe out there, and remember to hire the best home inspector you can find.  For more on our services, check out www.vhillc.com